• zipen

Quality Inspection For High Temperature Reactor - Homogeneous Reactor/Hydrothermal Reaction Rotary Oven – Zipen

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

The incredibly abundant projects administration experiences and 1 to one provider model make the superior importance of small business communication and our easy understanding of your expectations for HP Compact Reactor, Teflon Lined Reactor, Polymer Reactor Tank, Our Lab now is "National Lab of diesel engine turbo technology " , and we own a professional R&D team and complete testing facility.
Quality Inspection For High Temperature Reactor - Homogeneous Reactor/Hydrothermal Reaction Rotary Oven – Zipen Detail:

The Homogeneous Reactor is used on reaction test for the same group of media under different conditions or the different group of media under same conditions.

The homogeneous reactor is composed of cabinet body, rotating parts, heater and controller. The cabinet body is made of stainless steel. The rotating system consists of motor gear box and rotary support. The control system mainly controls the cabinet temperature and rotating speed. The homogeneous reactor used multiple hydrothermal synthesis reactor vessels to test the same group of media under different conditions or the different group of media under same conditions. Due to the rotating shaft, the medium in the reactor vessel is fully stirred, so the reaction speed is fast and reaction is fully and thoroughly, which is better than the simple thermostatic effect. The casing on the stirring rod is equipped with a retainer ring (according to the size of the reaction vessel), can be fixed micro reaction vessel 6,8,10,12, at the same time, can be customized according to user requirements. In general, the cabinet body size is 400*400*450mm, and the inside of the cabinet can be filled with 8 pieces 100ML reactor vessel. The specific size is subject to the customer’s demand.

Technical parameter

Hydrothermal Synthesis Reactor Unit
Model ZP-4/6/8/12
Working Voltage 220×(1±10%)V, AC 50Hz/60Hz
Design Temperature 300℃
Operating Temperature ≤200℃ (Teflon inner vessel)
Temperature Fluctuation ±0.5℃
Motor Speed 0-70r/min
Material 304 Stainless Steel
Retainer rings 4/6/8/12
Control System Side control box

What’s the Homogeneous Reactor?

Homogeneous Reactor is used on reaction test for the same group of media under different condition or the different group of media under same conditions. It is made of stainless steel and double-toughened glass, the test process is continuously circulated in the close environment, in this case, the temperature in the cabinet becomes equal as well.

1.Three-dimensional Rotating Shaft;

Three-dimensional Rotating Shaft

Hydrothermal synthesis reactor

Hydrothermal synthesis reactor

3.Motor

Motor

Our Advantage of Hydrothermal Synthesis Reactor Unit?

1. Our product is made of stainless steel, which can avoid any rust or corrosion.
2. The rotating shaft makes the reaction speed fast, fully and thoroughly, which is better than the simple thermostatic effect.
3. The high quality high temperature resistance handle can avoid any scald efficiently.


Product detail pictures:

Quality Inspection For High Temperature Reactor - Homogeneous Reactor/Hydrothermal Reaction Rotary Oven – Zipen detail pictures

Quality Inspection For High Temperature Reactor - Homogeneous Reactor/Hydrothermal Reaction Rotary Oven – Zipen detail pictures


Related Product Guide:

We take pleasure in an extremely fantastic standing among the our prospects for our great product top quality, competitive cost and the finest support for Quality Inspection For High Temperature Reactor - Homogeneous Reactor/Hydrothermal Reaction Rotary Oven – Zipen , The product will supply to all over the world, such as: Marseille, kazakhstan, New Zealand, Due to our dedication, our products are well known throughout the world and our export volume continuously grows every year. We will continue to strive for excellence by providing high quality products that will exceed the expectation of our customers.
  • A good manufacturers, we have cooperated twice, good quality and good service attitude.
    5 Stars By Elizabeth from Cancun - 2017.03.08 14:45
    With a positive attitude of "regard the market, regard the custom, regard the science", the company works actively to do research and development. Hope we have a future business relationships and achieving mutual success.
    5 Stars By Matthew from Angola - 2018.06.18 17:25
    Write your message here and send it to us

    Related products

    • Wholesale Dealers Of Hydrothermal Synthesis Vessel/Tank - Hydrogen Peroxide Stabilizer – Zipen

      Wholesale Dealers Of Hydrothermal Synthesis Ves...

      Specification TYPE II Stannum containing stabilizer Appearance Light yellow transparent liquid Density (20℃)  ≥1.06g/cm3 PH value  1.0~3.0 Stabilizing effect on hydrogen peroxide   the stability of hydrogen peroxide is increased from ≥ 90.0% to ≥ 97.0% TYPE IV Phosphorus containing stabilizer Appearance colorless transparent liquid Density (20℃)  ≥1.03g/cm3 PH value  1.0~2.0 Stabilizing effect on hydrogen peroxide   the stability of hydrogen peroxide is i...

    • Special Design For 2-Ethyl-Anthraquinone - Hydrogen Peroxide Production Material 2-ethyl-Anthraquinone  – Zipen

      Special Design For 2-Ethyl-Anthraquinone - Hyd...

      Package 25kg/ Kraft paper bag with black PE bag lined or according to your requirement. Storage The products shall be stored in a dry and ventilated warehouse. Specification Appearance yellowish solid flakes  Melting Point 109~111 ℃ EAQ content ≥  98.5 %  Benzene-insoluble ≤ 0.05 % Cl content ≤ 40 ppm S content ≤ 5 ppm Fe content ≤ 5 ppm Packing

    • Factory Promotional HT Reactor - Pilot/Industrial magnetic stirred reactors – Zipen

      Factory Promotional HT Reactor - Pilot/Industr...

      The reactor is widely used in petroleum, chemical, rubber, pesticide, dye, medicine, food and is used to complete the pressure vessel of vulcanization, nitrification, hydrogenation, alkylation, polymerization, condensation, etc. According to different production processes, operating conditions, etc, the design structure and parameters of the reactor are different, that is, the structure of the reactor is different, and it belongs to non-standard container equipment. The materials generally in...

    • Low MOQ For Bench Top Reactor - Hydrothermal Synthesis Reactors – Zipen

      Low MOQ For Bench Top Reactor - Hydrothermal S...

      The hydrothermal synthesis reactor unit can be used to test the same group of media under different conditions or the different group of media under same conditions. The hydrothermal synthesis reactor unit is composed of cabinet body, rotating system, heating system and control system. The cabinet body is made of stainless steel. The rotating system consists of motor, gear box and rotary support. The control system mainly controls the cabinet temperature and rotating speed. The hydrothermal s...

    • China Factory For Continuous Stirred Tank Reactor - Hydrothermal Synthesis Reactors – Zipen

      China Factory For Continuous Stirred Tank React...

      The hydrothermal synthesis reactor unit can be used to test the same group of media under different conditions or the different group of media under same conditions. The hydrothermal synthesis reactor unit is composed of cabinet body, rotating system, heating system and control system. The cabinet body is made of stainless steel. The rotating system consists of motor, gear box and rotary support. The control system mainly controls the cabinet temperature and rotating speed. The hydrothermal s...

    • Best Quality Px Experiment - Hydrogen Peroxide Production Material 2-ethyl-Anthraquinone  – Zipen

      Best Quality Px Experiment - Hydrogen Peroxide...

      Package 25kg/ Kraft paper bag with black PE bag lined or according to your requirement. Storage The products shall be stored in a dry and ventilated warehouse. Specification Appearance yellowish solid flakes  Melting Point 109~111 ℃ EAQ content ≥  98.5 %  Benzene-insoluble ≤ 0.05 % Cl content ≤ 40 ppm S content ≤ 5 ppm Fe content ≤ 5 ppm Packing