OEM/ODM Manufacturer Polyether Reaction - Catalyst evaluation system – Zipen
OEM/ODM Manufacturer Polyether Reaction - Catalyst evaluation system – Zipen Detail:
This system is mainly used for the performance evaluation of palladium catalyst in hydrogenation reaction and the exploration test of process conditions.
Basic process: The system provides two gases, hydrogen and nitrogen, which are respectively controlled by a pressure regulator. The hydrogen is metered and fed by a mass flow controller, and the nitrogen is metered and fed by a rotameter, and then passed into the reactor. The continuous reaction is carried out under the conditions of temperature and pressure set by the user.
Operating characteristics: The pressure stability of the system is precisely controlled by the cooperation of the inlet gas pressure control valve and the vent gas counterbalance valve. Temperature control adopts PID intelligent temperature control meter to control electric heating elements. For the temperature runaway caused by the exotherm in the reaction process, the computer will automatically complete the PID control by regulating the cooling water flow according to the degree of temperature runaway. The whole system integrates temperature, pressure, stirring, flow control, inlet gas pressure regulation, and pressure counterbalance into a cabinet.
The overall dimensions are 500*400*600.
Product Description
The pressure stability of the system is precisely controlled by the cooperation of the inlet gas pressure control valve and the vent gas counterbalance valve; The hydrogen gas flow is accurately measured by Brooks flowmeter, which is equipped with a bypass and a manual micro-control valve; According to the features of hydrogenation reaction, the control of reaction temperature is realized through PID control of the heating furnace and the cooling water flow rate as well as temperature runaway. The whole set of equipment is integrated in an overall frame, easy for installation and operation, safe and reliable.
Technical Specification
Reaction pressure | 0.3MPa (3 bar) |
Design pressure | 1.0MPa (10 bar) |
Reaction temperature | 60℃, accuracy: ±0.5℃ |
Temperature runaway control | Automatically control the cooling water flow, temperature runaway<2℃ |
Stirring speed | 0-1500r/min |
Effective volume | 500ml |
Inserted filter in reactor | 15~20μm |
Range of gas mass flow controller | 200SCCM |
Flow range of Rotameter | 100ml/min |
Pneumatic cooling water control valve | CV: 0.2 |
Product detail pictures:
Related Product Guide:
Our pursuit and enterprise goal is to "Always satisfy our customer requirements". We keep on to establish and style and design outstanding top quality goods for both our outdated and new prospects and realize a win-win prospect for our clientele likewise as us for OEM/ODM Manufacturer Polyether Reaction - Catalyst evaluation system – Zipen , The product will supply to all over the world, such as: Sydney, Cyprus, Peru, With a wide range, good quality, reasonable prices and stylish designs, our solutions are extensively used in beauty and other industries. Our solutions are widely recognized and trusted by users and can meet continuously changing economic and social needs.
By Eve from Eindhoven - 2017.05.02 18:28
Sales manager is very enthusiastic and professional, gave us a great concessions and product quality is very good,thank you very much!
By Beryl from Tajikistan - 2017.12.02 14:11