• zipen

Experimental rectification system

Short Description:

The system is a continuous neopentyl glycol NPG rectification unit automatically controlled by a computer, which consists of four parts: material preparation unit, material feeding unit, rectification tower unit and product collection unit. The system is available for both remote control by means of IPC and manual control by means of on-site control cabinet.


Product Detail

Product Tags

Product performance and structural features

The material feeding unit is composed of a raw material storage tank with stirring and heating and temperature control, together with Mettler's weighing module and the precise measurement of a micro-metering advection pump to achieve micro and stable feeding control.

The temperature of the rectification unit is achieved by the comprehensive cooperation of preheating, tower bottom temperature control and tower temperature control. The tower top condenser needs to maintain a certain temperature during condensation, which is achieved by an external oil bath circulator.

The reflux ratio control is realized by the reflux head with heat and heat preservation and the controller. The vacuum of the system is realized by a vacuum pump with variable frequency speed regulation. The whole set of equipment adopts the control mode that the on-site control cabinet and the remote computer cooperate with each other, which can be operated on-site, but also can realize the remote automatic control of the computer. At the same time, it saves historical data and curves for analysis and calculation. The whole set of equipment is integrated in an overall frame, easy to operate, safe and reliable.

Design conditions and technical parameters

Design pressure -0.1MPa, reaction pressure: -0.1MPa (MAX) 
Design temperature room temperature -300℃ 
Tower kettle working temperature 250℃ (MAX) 
Distillation tower working temperature 200℃ (MAX) 
Distillation tower DN40*700 has four sections, which can be assembled into three or two sections
Processing capacity 1~2kg/h neopentyl glycol

Public works requirements

This device requires the user to provide the following infrastructure:
Power supply: 380 VAC / 3 phase / 50 Hz
Cable: 3*16 square +2
Nitrogen gas source
Cooling water source


  • Previous:
  • Next:

  • Write your message here and send it to us

    Related products

    • Pilot Reactor for PX Oxidation continuous experiment

      Pilot Reactor for PX Oxidation continuous exper...

      Basic process: Preheat the system, and purge it with nitrogen until the oxygen content of the outlet tail gas is zero. Add liquid feed (acetic acid and catalyst) into the system and continuously heat the system to the reaction temperature. Add pure air, continue heating until the reaction is triggered, and start insulation. When the liquid level of reactants reaches the required height, start to control the discharge, and control the discharge speed to keep the liquid level stable. In the who...

    • Experimental nitrile latex reaction system

      Experimental nitrile latex reaction system

      Basic Process Butadiene in the raw material tank is prepared in advance. At the beginning of the test, the system is vacuumed and replaced with nitrogen to ensure that the entire system is oxygen-free and water-free. Prepared with various liquid-phase raw materials and initiators and other auxiliary agents are added to the metering tank, and then the butadiene was transferred to the metering tank. Open t...

    • Experimental polyether reaction system

      Experimental polyether reaction system

      Product Description The whole set of reaction system is integrated on a stainless-steel frame. The PO/EO feeding valve is fixed on the frame to prevent the electronic scale measurement from being affected during operation. The reaction system is connected with stainless steel pipeline and needle valves, which is easy for disconnection and re-connection. The operating temperature, feeding flow rate, and P...

    • Experimental PX continuous oxidation system

      Experimental PX continuous oxidation system

      Product Description The system adopts modular design concept, and all the equipment and pipelines are integrated in the frame. It includes three parts: feeding unit, oxidation reaction unit, and separation unit. Using advanced control technology, it can meet the special requirements of complex reaction system, high temperature and high pressure, explosiveness, strong corrosion, multiple constraint condit...

    • Polymer polyols (POP) reaction system

      Polymer polyols (POP) reaction system

      Product Description This system is suitable for continuous reaction of gas-liquid phase materials under high temperature and high pressure. It is mainly used in the exploration test of POP process conditions. Basic process: two ports are provided for gases. One port is nitrogen for safety purge; the other is air as power source of pneumatic valve. The liquid material is accurately metered by an electroni...

    • Experimental Nylon reaction system

      Experimental Nylon reaction system

      Product Description The reactor is supported on the aluminum alloy frame. The reactor adopts a flanged structure with a reasonable structure and a higher degree of standardization. It can be used for chemical reactions of various materials under high temperature and high pressure. It is especially suitable for stirring and reaction of high-viscosity materials. 1. Material: The reactor is mainly made of S...