Experimental nitrile latex reaction system
Basic Process
Butadiene in the raw material tank is prepared in advance. At the beginning of the test, the system is vacuumed and replaced with nitrogen to ensure that the entire system is oxygen-free and water-free. Prepared with various liquid-phase raw materials and initiators and other auxiliary agents are added to the metering tank, and then the butadiene was transferred to the metering tank.
Open the oil bath circulation of the reactor, and the temperature in the reactor is controlled at 75°C. The valve is manually opened to control the dripping of raw materials. The flow is controlled by the opening of the feed valve and the level gauge of the metering tank.
Main Specification
1. 15L reactor
Speed: 0~750 rpm
Mixing: 0.75KW explosion-proof
Upgrade: 370W explosion-proof
Wrench M16
2. Rapture Disc
Temperature 200℃, pressure 19Bar
3. Platinum resistance PT100
Maximum working temperature 200℃ φ3*500
4. Three-piece welded ball valve
DN20, temperature range -25~200℃, pressure resistance 5Bar